Beurer blood pressure monitor manual




















Velcro fastener. The cuff should be fitted tight enough to allow just two fingers to fit beneath the cuff. Insert the cuff tubing into the socket for the cuff attachment on the left side of the unit. Make sure. Important: This device should only be operated with the original cuff. The cuff included with the device is suitable for an upper arm circumference of 8. Replacement cuffs from other models cannot be used with this model. Doing so, will result in inaccurate readings or error messages.

The most precise measurement results are obtained if you strive for a relaxed measurement situation. If you are using the unit for the first time, please remove the protective film from the display.

Cuff air pressure is released slowly. As described above, attach the cuff and adopt the posture in which you want to perform the measurement. All display elements are briefly displayed. As soon as a pulse is found, the pulse symbol is displayed. If you do not select a user memory, the measurement is stored in the. The relevant symbol or appears on the display. The measurement is then stored in the selected user memory. In this case too, the value is stored in the selected or most recently used user memory.

The results of every successful measurement are stored together with the date and time. To do this press the. Average values. If you have selected user memory , the M1 memory button must be pressed. The average value of all saved measured values in this user memory is displayed. The average value of the morning measurements for the last 7 days is displayed morning: 5. The average value of the evening measurements for the last 7 days is displayed evening: 6.

Deleting measured values Individual measured values. A single measurement does not provide an accurate indication of your true blood pressure. Please note that you should rest at least 5 minutes between measurements and not talk or move during the measurement.

If the icon continues to be displayed in subsequent readings, we recommend you to consult your physician in order to determine if it is cause for concern.

Do not try to interpret readings or attempt to treat any condition yourself. Always follow the guidance of a health professional. If you have an emergency call immediately. The most frequent error made when measuring blood pressure is taking the measurement when not at rest haemodynamic stability , which means that both the systolic and the diastolic blood pressures are distorted.

While measuring the blood pressure, the device automatically determines whether you are at rest or not. GREEN: haemodynamically stable. Measurement of the systolic and diastolic pressure is increased when the circulatory system is sufficiently at rest and is a very reliable indicator of resting blood pressure.

However, if there is an indication that the circulatory system is not sufficiently at rest haemodynamic instability , the symbol lights up red. In this case, the measurement should be repeated after a period of physical and mental rest. The blood pressure. RED: lack of haemodynamic stability.

It is very probable that the systolic and diastolic blood pressures have not been measured whilst the patient is at rest and the resting blood pressure measurement has therefore been distorted. Repeat the measurement after a rest and relaxation period of at least five minutes.

Go to a sufficiently quiet and comfortable spot and remain there calmly; close your eyes, breathe deeply and evenly and try to relax. If the next measurement also shows insufficient stability, you can repeat the measurement after another resting. If the measurements continue to show some instability, identify these blood pressure measurements as having been taken when the circulatory system had not been sufficiently rested. In this case, nervousness or inner anxiety may be the cause and this cannot be cured by brief periods of rest.

Existing cardiac arrhythmias may also prevent a stable blood pressure measurement. A lack of resting blood pressure can have various causes, such as physical or mental strain or distraction, speaking or experiencing cardiac arrhythmias during the blood pressure measurement. In an overwhelming number of cases, the HSD diagnosis will give a very good guide as to whether the circula-. Certain patients suffering from cardiac arrhythmia or chronic mental conditions can remain haemodynamically unstable in the long-term, something which persists even after repeated periods of rest.

The accuracy of the resting blood pressure results is reduced in these users. Like any medical measurement method, the precision of the HSD diagnosis is limited and can lead to incorrect results in some cases.

The blood pressure measurements taken when the circulatory system was at rest represent particularly reliable results. Please consult your physician for proper diagnosis.

The bar graph in the display and the scale on the unit indicate the range of the blood pressure which has been recorded. If the values for systolic and diastolic pressure are in two different WHO ranges e. Further documents which include information for the Calibration of the device can be asked at the service address. The device can be tested in case of supposed inaccuracy every two years.

Please contact the nearest service address. To keep your blood pressure monitor in the best condition and protect the unit from damage follow the directions listed below:.

Observe the local regulations for material disposal. Dispose of the device in accordance with local regulations. If you have any questions, please contact the local authorities responsible for waste disposal. Technical alarm — description.

In such cases, you should seek medical assistance and check the accuracy of your procedure. The limit values for the technical alarm are factory set and cannot be adjusted or deactivated. These alarm limit values are accorded second priority under the standard IEC The technical alarm is a non-locking alarm and must not be reset. The signal shown on the display will disappear automatically after about 8 seconds.

These specifications are subject to change without notice for purpose of improvement. The serial number can be found on the unit itself or in the battery compartment. Please note that portable and mobile HF communication systems may interfere with this instrument. For more details, please contact customer service at the address indicated. These limits are designed to provide reasonable protection against harmful interference in a residential installation.

This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:.

The cuff is warranted to be free from defects in materials and workmanship appearing within two years from date of purchase when the monitor is used in accordance with the instructions provided with the unit.

This warranty extends only to the original retail purchaser and does not extend to retailers or subsequent owners. We will, at our option, repair or replace the Beurer Blood Pressure Monitor, Model BM 55, without additional charge, for any part or parts covered by these written warranties.

No refunds will be given. Repair or replacement is our only responsibility and your only remedy under this written warranty. If replacement parts for defective materials are not available, Beurer reserves the right to make product substitutions in lieu of repair or replacement. For warranty service contact our customer service department at or at info beurer.

If the problem is deemed to be within the scope of the limited lifetime warranty, you will be asked to mail the product at your costs in its original package with proof of purchase, your name, address and.

Subject to error and change. If the problem is not deemed to be within the scope of the limited lifetime warranty, we will provide a quotation for repair, respectively, replacement and return shipping fees.

This warranty is void if the product is ever used in a commercial or business environment. The maximum liability of Beurer under this warranty is limited to the purchase price actually paid by the customer for the product covered by the warranty, as confirmed by proof of purchase, regardless of the amount of any other direct or indirect damage suffered by the customer.

This warranty is effective only if the product is purchased and operated in the country in which the product is pur. Some states do not allow limitations on how long an implied warranty lasts, so the above limitations may not apply to you. Some states do not allow the exclusion or limitation of special, incidental, or consequential damages, so the above limitation may not apply to you. Beurer does not authorize anyone, including, but not limited to, retailers, the subsequent consumer purchaser of.

Device description Preparing the measurement Measuring blood pressure Evaluating results Saving, displaying and deleting measured values Cleaning and storing the device and cuff Technical specifications Replacement parts and wearing parts Dear customer, Thank you for choosing one of our products.

With kind regards, Your Beurer team 1. Getting to know your device Check that the device packaging has not been tampered with and make sure that all contents are present. Important notes Signs and symbols The following symbols are used in these instructions for use, on the packaging and on the type plate for the device and the accessories: Attention Note Note on important information Observe the instructions for use Application part, type BF Direct current.

The accuracy of the measured values and service life of the device depend on its careful handling: — Protect the device from impacts, humidity, dirt, marked temperature fluctuations and direct sunlight. You can only view or download manuals with. Sign Up and get 5 for free. Upload your files to the site.

You get 1 for each file you add. Get 1 for every time someone downloads your manual. Buy as many as you need. View and download manuals available only for. Register and get 5 for free. Irregular Heartbeat Indicator 3. Air Tube Connector 6. Battery Level Indicator 4. Page Measuring Blood Pressure 6. The hour flashes on the LCD Display. The minutes flash on the LCD Display. Set the min- 0. Only use original Beurer cuffs with this device.

The Select a User Memory included cuff is suitable for an arm circumference of This unit has four user numbers, each with 30 stor- 8.

Page Evaluating Results 8. Evaluating Results treatment based solely on the test results may be dan- gerous. Page Displaying And Deleting Measurements 9. Displaying and Deleting Meas- Blood pres- Systole Diastole sure value Action urements in mmHg in mmHg category regular mon- User Memory: High normal — 85 — 89 itoring by doc- Every successful measurement is stored along with its date and time. Page 21 You can exit the menu at any time by pressing the properly. Page Care And Maintenance not be used as a basis for therapeutic treatments.

In such cases, repeat the measurement. Do not move or speak. If necessary, replace the batteries. Page 23 Measurement Max. Page Fcc Statement FCC Statement with regard to electromagnetic compatibility. Please note that portable and mobile HF communication Changes or modifications to the product not express- systems may interfere with this unit. Page Warranty We will, at our option, repair or replace the Beurer stallation; misapplication; lack of reasonable care with Blood Pressure Monitor, Model BM 67, without addi- respect to the product; Page 27 Beurer in any way beyond the terms set Made in China.

Questions or comments? Call toll free This warranty does not extend to the purchase of or contact info beurer. Cuidado y mantenimiento Si se le presenta una sar efectos secundarios serios de la lectura, por emergencia, llame al de inmediato.

Deseche el dispositivo, componentes y en estas instrucciones. No lo presione. Con- pecifican. Contenido del paquete 1. Lista de dispositivos compatibles: 1. El brazalete incluido es adecuado pa- Seleccione una memoria de usuario.

Page Cuidado Y Mantenimiento